Ibrahim Neya, Daniel Yamegueu, Adamah Messan, Yezouma Coulibaly, Arnaud Louis Sountong-Noma Ouedraogo and Yawovi Mawuénya Xolali Dany Ayite

The stabilization of earthen blocks improves their mechanical strength and avoids adobe construction erosion due to rainwater. However, the stabilization affects the thermal…

Abstract

Purpose

The stabilization of earthen blocks improves their mechanical strength and avoids adobe construction erosion due to rainwater. However, the stabilization affects the thermal properties of the earthen blocks, and thus their capacity to provide adequate thermal comfort to occupants. This article examines the influence of cement and geopolymer binders on thermal comfort in compressed earthen buildings in hot and arid climates.

Design/methodology/approach

The test cell is on the building platform in Burkina Faso. The building is made of compressed earth blocks (CEB) consisting of laterite, water and binder. The thermal models of the building were implemented in EnergyPlus v9.0.1 software. Empirical validation is used to check whether the model used for the thermal dynamic simulation can reproduce with accuracy the thermal behavior in a real situation. The adaptive thermal comfort model of ASHRAE 55–2010 was used to assess thermal comfort in long-term hot and dry tropical conditions.

Findings

The results show that the CEB buildings remain hot despite the use of cement or geopolymer binder. Indeed, with both cement and geopolymer binders, on a daily basis, 19 h and 15 h are uncomfortable during, respectively, the hot and cold seasons. An increase of 1% in cement content raises the comfort hours by 9.2 h during the hot season and 11.7 h during the cold season. Hence, the comfort time varies linearly with the cement content in the building material. Moreover, there is no linear relationship between comfort time and geopolymer rate.

Research limitations/implications

Complementary work should also assess the influence of stabilization on building humidity levels. In fact, earthen materials are very sensitive to outdoor humidity and indoor humidity affects thermal comfort even if it is not taken into account in the ASHRAE adaptive thermal comfort model.

Practical implications

The present study will certainly contribute to a better valorization of clay potential in countries with similar climatic conditions.

Social implications

The use of geopolymer binder is a suitable ecological option to replace the cement binder. It is important to mention that nighttime comfort can be increased through passive strategies such as natural ventilation.

Originality/value

Most CEB material stabilization analyses including cement and geopolymer ones were mostly investigated at the laboratory scale and less at the building scale. Also, the influence of the binder rate on the thermal performance of buildings made of cement and geopolymer has not yet been assessed. This paper fills this gap of knowledge by assessing the impact of cement and geopolymer binder rates on the thermal comfort of CEB dwellings.

Details

International Journal of Building Pathology and Adaptation, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2398-4708

Keywords

Article
Publication date: 21 May 2021

Arnaud Louis Sountong-Noma Ouedraogo, Adamah Messan, Daniel Yamegueu and Yezouma Coulibaly

A major challenge faced by West Africa is to find comfortable housing as a result of climate change and population growth. The climatic adaptation of buildings and their indoor…

Abstract

Purpose

A major challenge faced by West Africa is to find comfortable housing as a result of climate change and population growth. The climatic adaptation of buildings and their indoor environment become an essential condition for maintaining the health and productivity of the occupants. This paper proposes a model to assess the thermal comfort of naturally ventilated buildings in hot and dry climates in Burkina Faso.

Design/methodology/approach

The proposed method is an adaptive model which relies on a combination of parameters such as the operative temperature, the new effective temperature and the basic parameters of thermal comfort. It consists in proposing the zones of thermal comfort on the diagram of the humid air for each climatic region.

Findings

A decision-making tool is set up for evaluating the comfort of buildings to better consider the bio-climatic concept through a long-term comfort index. This comfort index is defined and is used to assess the degree of thermal discomfort for various types of housing. Two natural ventilation pilot buildings located in Ouagadougou were considered. The results show that the pilot building whose wall are is made of Earth blocks achieves 26.4% of thermal comfort while the building made of hollow cement block achieves 25.8% of thermal comfort.

Originality/value

The decision-making tool proposed in the present study allow building stakeholders to better and easily design, assess and improve the thermal environment of buildings.